Joint work: Karl Böhringer, Bruce Darling, Bruce Donald, Greg Kovacs, John Suh.
Distributed manipulation experiments were performed using a massively-parallel, microfabricated actuator array. An organic ciliary array of thin-film polyimide bimorph microactuators exploiting combined thermal and electrostatic control was employed to implement sensorless manipulation strategies for small objects. The tasks of parts-translation, -rotation, -orientation, and -centering were demonstrated using small integrated circuit (IC) dice.
The micromanipulation device (consisting of 4 quadrants of 8 × 8 motion pixels for a total of 256 microactuators) was connected to a PC via the parallel port. Micromanipulation strategies were programmed in a finegrained SIMD (single instruction, multiple data) fashion by specifying programmable force fields. When a part is placed on the device, the programmed vector field induces a force and moment upon it. The part's equilibrium states may be predicted and cascaded (using a sequence of fields) to bring the part to a desired final state.
The experiments suggest that MEMS actuator arrays are useful for parts-orientation, -posing, -transfer, -singulation, and -sorting.
To induce motion on a part that is placed on the array, the cilia are actuated in a cyclic, gait-like fashion (see Figure 3). In each cycle, the part is moved in a certain direction by the motion of the actuators that are in contact with it. The speed of the moving part depends on the (horizontal) displacement of the actuators per cycle as well as the frequency of cycle repetition. It also depends on the surface properties and weight of the moving part. Motion in non-principal (e.g. diagonal) directions was effected by a pairwise coupling of neighboring cilia to implement "virtual cilia."
![]() |
![]() |
![]() |
![]() |
| Figure 4: Manipulation of silicon chips in programmable vector fields induced by a micro cilia array (microscope video images). The chip is aligned with the vertical squeeze line of the field. (Figures by John Suh.) | |||
If a part is placed in a squeeze field, it will translate and rotate until a stable equilibrium is reached. Parts may exhibit several equilibria, hence after one squeeze the part orientation may be ambiguous. This ambiguity can be removed with programmable force field strategies: by executing a sequence of squeezes at particular angles, the part is uniquely oriented.
Experiments and Results: The long, thin part depicted in Figure 4 exhibits a unique stable equilibrium (modulo 180° field symmetry). When placed in a squeeze field, its longitudinal axis aligns with the squeeze line. This dynamical process was predicted by simulation (see Figure 5), and verified in experiment (see Figure 4). Part alignment experiments have also been performed with similar results for several other small pieces of glass and silicon of a few mm length and several mg of mass. It usually takes about 1 - 2 min to reach equilibrium.
Certain parts will rotate indefinitely in skewed squeeze fields (see Figure 7). Note that even though our cilia device has more degrees of freedom, two areas of constant force are sufficient to implement a skewed field, resulting in a very simple rotation strategy. In particular, the rotation algorithm resulting from the application of skew-symmetric squeeze fields is simpler than rotation with four-quadrant vortices.
Experiments and Results: Figure 7 shows video frames of a 3 × 3 mm2 IC chip rotating on the squeeze line of a skewed field. During the experiments of approximately 10 min, several full rotations of the part were performed.
![]() |
![]() |
![]() |
![]() |
| Figure 7: Rotating a square-shaped chip counterclockwise in a skewed squeeze field. In a skewed squeeze field, the forces do not point perpendicularly towards the squeeze line, but instead are symmetrically skewed. (Figures by John Suh.) | |||
Webpage design courtesy of Karl Böhringer.
Quicktime Movies courtesy of Tom Dooley and Fred Henle.
Thanks!